Vertical and horizontal Air flow clean bench medical lab equipment
Product Description
SW-CJ-1FB single-person double-side (vertical and horizontal air supply) clean bench
Working Principle
First, the air is inhaled through the fan and then filtered by the Hepa filter through the static pressure box. After that the
filtered clean air is sent out in the state of vertical or horizontal air flow, so that the operation area continues to reach the
100-level cleanliness under the control of clean air and to ensure the production of environmental cleanliness requirements.
Application Range
The vertical flow clean bench is noisy than horizontal clean bench because its fan is installed at the top. The wind blowing
vertically so it is often used in medical engineering to ensure the operator’s health.
Vertical laminar flow clean bench is widely used in areas requiring partial cleaning, laboratories, biopharmaceuticals,
optoelectronics, microelectronics, hard disk manufacturing and other fields.
Horizontal flow work bench noise is compared small, so it is usually used in electronic industry, which has little effect to
health.
Horizontal laminar flow is widely used in electronics, national defense, precision instruments, meters, pharmaceutical industries,
etc.
Characteristics
1. Adopt Arbitrary positioning sliding door system
2. The shell is made of colored steel plate, and the working table is SUS304 brushed stainless steel, which is corrosion resistant
and easy to clean
3. Lighting and sterilization system safety interlock
4. Digital explicit liquid crystal control panel. Three stages wind speed(fast, medium and slow ). Except SW-CJ-1D and SW-CJ-1G
which only has two stages of wind speed.
5. Vertical quasi-closed table, air curtain stroke of downdraft in the operation room, which can effectively prevent external gas
input to keep the operation area clean
6.Equipped with HEPA filter. With primary filter for preliminary filtration, which can effectively extend the life span of HEPA
filter
7. Though both vertical and horizontal air flow are available, you can only choose to use vertical air flow or horizontal at a
time.
First, the air is inhaled through the fan and then filtered by the Hepa filter through the static pressure box. After that the
filtered clean air is sent out in the state of vertical or horizontal air flow, so that the operation area continues to reach the
100-level cleanliness under the control of clean air and to ensure the production of environmental cleanliness requirements.
Application Range
The vertical flow clean bench is noisy than horizontal clean bench because its fan is installed at the top. The wind blowing
vertically so it is often used in medical engineering to ensure the operator’s health.
Vertical laminar flow clean bench is widely used in areas requiring partial cleaning, laboratories, biopharmaceuticals,
optoelectronics, microelectronics, hard disk manufacturing and other fields.
Horizontal flow work bench noise is compared small, so it is usually used in electronic industry, which has little effect to
health.
Horizontal laminar flow is widely used in electronics, national defense, precision instruments, meters, pharmaceutical industries,
etc.
Characteristics
1. Adopt Arbitrary positioning sliding door system
2. The shell is made of colored steel plate, and the working table is SUS304 brushed stainless steel, which is corrosion resistant
and easy to clean
3. Lighting and sterilization system safety interlock
4. Digital explicit liquid crystal control panel. Three stages wind speed(fast, medium and slow ). Except SW-CJ-1D and SW-CJ-1G
which only has two stages of wind speed.
5. Vertical quasi-closed table, air curtain stroke of downdraft in the operation room, which can effectively prevent external gas
input to keep the operation area clean
6.Equipped with HEPA filter. With primary filter for preliminary filtration, which can effectively extend the life span of HEPA
filter
7. Though both vertical and horizontal air flow are available, you can only choose to use vertical air flow or horizontal at a
time.
Model | SW-CJ-1FB |
Clean grade | Grade 100(209 E U.S. Federal) |
Number of bacteria | ≤0.5per utensil.hour(90mm utensil) |
Noise | ≤62dB |
Power | 220V/50HZ |
Wind speed | 0.25-0.45m/s |
illumination | ≥300LX |
Working area dimension(W*D*H) | 870*510*600mm |
Overall dimension(W*D*H) | 1025*745*1815mm |
HEPA filter size and quantity | 865*600*38*1pc/865*484*38*1PC |
Fluorescent/UV lamp specifications and quantity | 20W*1PC / 20W*1PC |
Operator | one person |
Product Categories : Laminar flow cabinet/Clean bench > Vertical and Horizontal clean bench
Premium Related Products
Other Products
Hot Products
10tph Dry Mortar Plough MixerLiquid Dryer MachineFluidizied Bed Dryer MachineFruit Vacuum DryerVegetable Drying MachineHot Air FurnaceSawdust Dedicated Drying Machine6m3 Twin Shaft Agravic Paddle MixerBiomass Grain Dryer Batch Type Circulating480 Bags Air Tank Type Dust Collector30tph Plastering Mortar Production LineDry Mixed Mortar Production Line25kg Valve Bag Dry Mortar Packing Machine60tph Rotary Drum Sand Dryer with Gas Burner60m Belt Type Chainboard Type Bucket Elevator for SandBolted Type Cement Silo for Concrete Mix Plant